Manna Gum House

Single Dwelling
Passivhaus Plus
Warragul, VIC, 2023

Our clients were first and foremost seeking a high-performing certified Passivhaus to ensure their health and comfort. The owners approached North South Homes to execute their dream of building and living in a Passivhaus. To them, a Passivhaus would answer their needs to have a home that encompasses not only sustainable building practices and running costs but also allows them year round comfort and, in particular, a healthy living environment.

 
 
  • AIRTIGHTNESS n50 ACH@50pascals: 0.36
    HEATING DEMAND (kWh/m².yr):
    22
    COOLING DEMAND (kWh/m².yr):
    8
    HEATING LOAD (W/m²):
    10
    COOLING LOAD (W/m²): 14
    PRIMARY ENERGY DEMAND (PE) (kWh/m².yr):
    104
    PRIMARY ENERGY RENEWABLE DEMAND (PER):
    46
    PRIMARY ENERGY RENEWABLE GENERATION (PER):
    70

  • LOCATION: Warragul, VIC
    NCC CLIMATE ZONE:
    6– Mild temperate
    NATHERS CLIMATE ZONE:
    64
    YEAR OF COMPLETION:
    2023
    TREATED FLOOR AREA (PHPP sqm):
    161.2
    PROJECT TYPE:
    New Build
    SECTOR:
    Single Dwelling
    CONSTRUCTION TYPE:
    Timber Frame
    CERTIFICATION LEVEL/ ENERGY STANDARD:
    Passivhaus Plus
    THIRD PARTY CERTIFICATIONS:
    Nathers

  • MHRV SYSTEM: Zehnder 350
    DOMESTIC HOT WATER SYSTEM:
    Reclaim Energy Split Heat Pump with 315L Storage Tank REHP-CO2-315SST
    EXTERIOR WALL TYPE, U-VALUE:
    140×35 timber framing@600cc with R4.0 glasswool insulation, 0.251
    FLOOR SLAB TYPE, U-VALUE:
    Waffle pod slab with 50 mm XPS insulation, 0.371
    ROOF INSULATION TYPE, MANUFACTURER: R6.0 Glasswool Insulation
    ROOF CONSTRUCTION:
    Timber Rafters @600cc
    ROOF ENVELOPE U-VALUE:
    0.191
    WALL FRAME TYPE:
    Timber
    GLAZING TYPE, MANUFACTURER, G-VALUE, U G-VALUE, U W-Value:
    Triple glazing with low-e coatings, PressGlass, 0.53, 0.58, 1.04
    EXTERNAL DOOR TYPE, U D- Value,MANUFACTURER:
    Timber door, 1.15, Logikhaus

  • NUMBER OF MODULES: 20
    HEIGHT, WIDTH OF ONE MODULE (m, m) :
    1134 x 1762
    EFFICIENCY (%):
    98%

 
 
  • Custom joinery, custom cladding for facade, having clients completely on board with Passvhaus building practices

  • Challenges - PH Consultant Designer was overloaded with work, we struggled to get the PHPP Information in a timely manner. Lessons - Architect and Designers should not be doing PHPP consulting at the same time as designing. Hire an external PHPP Consultant, always.

 

Project Members

PASSIVHAUS CERTIFIER: Detail Green
PASSIVHAUS CONSULTANT/ DESIGNER: Passive Analytics
ARCHITECT/ BUILDING DESIGNER: 
Environmental Homes & Landscaping
CONTRACTOR/ BUILDER/ PROJECT MANAGER: 
North South Homes 
STRUCTURAL ENGINEER:
RMG
MECHANICAL ENGINEER:
Passivetech
ELECTRICAL ENGINEER:
JMC Electrics
ENVIRONMENTAL CONSULTANT:
EcoClimate
QUANTITY SURVEYOR: Holland Mitford Engineering Group
BLOWER DOOR TESTER: 
Passivetech

PHOTOGRAPHER: Susan Carmody & Hayleigh Bashaw

Awards and Shortlists

MBAV - Special Commendation for Best Custom Home $600,000-$800,000


Next
Next

ECHO.1