Residential: Single Dwelling
Passivhaus Classic Certification
Riddells Creek, VIC, 2023

This beautiful house consists of three bedrooms, two bathrooms, on 1000m2 of land in Riddells Creek, Victoria. Owners were looking for a more comfortable and energy-efficient home requiring minimal maintenance. Architect, builder, and consultant worked as a team to create and execute this exquisite design.

 
 
  • AIRTIGHTNESS n50 ACH@50pascals: 0.3
    HEATING DEMAND (kWh/m².yr):
    14.5
    COOLING DEMAND (kWh/m².yr):
    2
    HEATING LOAD (W/m²): 10
    COOLING LOAD (W/m²):
    9
    PRIMARY ENERGY DEMAND (PE) (kWh/m².yr): 67
    PRIMARY ENERGY RENEWABLE DEMAND (PER):
    30
    PRIMARY ENERGY RENEWABLE GENERATION (PER):
    38

  • LOCATION: Riddells Creek
    NCC CLIMATE ZONE:
    7 – Cool temperate
    NATHERS CLIMATE ZONE:
    60
    YEAR OF COMPLETION: 2023
    TREATED FLOOR AREA (PHPP sqm):
    152.8
    PROJECT TYPE:
    New Build
    RESIDENTIAL:
    Single Dwelling
    CONSTRUCTION TYPE:
    Timber Frame
    CERTIFICATION LEVEL/ ENERGY STANDARD:
    Passivhaus Classic

  • MHRV SYSTEM: Zehnder ComfoAirQ 350
    DOMESTIC HOT WATER SYSTEM:
    Reclaim 320 litre, Split Heat Pump
    EXTERIOR WALL TYPE, U-VALUE:
    Timber frame ,
    0.209
    FLOOR SLAB TYPE,U-VALUE:
    Insulated timber over concrete slab,0.403
    ROOF INSULATION TYPE, MANUFACTURER: Earthwool
    ROOF CONSTRUCTION:
    Timber frame
    ROOF ENVELOPE U-VALUE:
    0.116
    GLAZING TYPE, MANUFACTURER,U W-VALUE, G-VALUE, U G-VALUE :
    Triple, Logikhaus, 0.97,0.50,0.67 EXTERNAL DOOR TYPE, MANUFACTURER, U D-VALUE: Glazed Timber, Logikhaus,0.67

  • NUMBER OF MODULES: 15
    HEIGHT, WIDTH OF ONE MODULE (m, m) :
    1.134, 1.762
    HEIGHT OF ARRAY:
    3
    EFFICIENCY (%):
    95

 
 
  • This project consists of striking and unusual shape of the house to maximise use of site. Buffer walls were added to provide protection from prevailing winds.

  • Site orientation is to north-west. House was built on a previous farm dam, requiring significant number of concrete piers. Unusual shape to maximise use of site required extra work in layout and construction.

 

Project Members

PASSIVHAUS CERTIFIER: Luc Plowman, Detail Green
PASSIVHAUS CONSULTANT/ DESIGNER: John Beurle, Passive House Services
ARCHITECT/ BUILDING DESIGNER: 
Eve Strano, Etha Architecture
BUILDER: 
Stuart Lee, Enerhaus
PROJECT MANAGER:
Eve Strano
WINDOW SUPPLIER:
Logikhaus
HRV SUPPLIER: 
Fantec
BLOWER DOOR TESTER: Detail Green
PHOTOGRAPHER:
 Marnie Hawson

Awards and Shortlists

Australian Institute of Architecture, Victorian Chapter, Shortlisted for 2025 Sustainable Architecture Award


Submit your Project